Joint JILS IEEE 3 Phase Transformer Presentation
Michael would like to thank JILS and IEEE for the opportunity to present last year at their brand new lecture theatre in Market Street Sydney on three phase transformer harmonics.…
Michael would like to thank JILS and IEEE for the opportunity to present last year at their brand new lecture theatre in Market Street Sydney on three phase transformer harmonics.…
We have completed our largest and most complex projects to date and would like to thank our industry partners and stakeholders for these key achievements in 2019. In particular, we…
Michael Larkin is presenting a research paper today at the 9th International Conference on Power and Energy Systems (ICPES 2019) held at Murdoch University, Perth. This research paper is a…
Tortech has completed a new Innovative design - A Single Phase to Three Phase converter which plugs into a standard 10A 240V Australian outlet and produces a 3-Phase 41.5V supply…
Tortech has now in operation world class testing facilities for Three Phase Dry Type Transformers. This type of transformer has many advantages over the traditional Oil Filled Type Transformer including:…
Michael Larkin will be presenting a research paper titled: Core Loss Studies Using (Finite Element Method) FEM of a Three Phase Isolation Transformer Under Harmonic Conditions at the 9th International Conference…
We would like to thank Professor Phung and the students from UNSW electrical engineering attending our open day on Monday. We demonstrated sphere gap calibration, routine testing of three phase…
On 25th of July, Tortech's MD; Michael Larkin attended ‘The second panel discussion in UNSW Engineering's thought leadership series – Engineering the Future". The topic of conversation for the evening…
On the 3rd of May 2019, Michael Larkin visited Macquarie University to conduct his presentation on 'Transformers from Faraday to the Future. What's Next?'. This presentation was held in an…
On the 1st March, the Managing Director of Tortech Michael Larkin was invited as a guest speaker to deliver a presentation at an Engineers Australia conference. This presentation was on…
Item 1 – Cast Resin type Isolation Transformer | HV Winding 1 | LV Winding 1 | LV Winding 2 | |
Rated power | kVA | 315 | 1250 | 1250 |
Rated voltage | kV | 33 | 0.48 | 0.48 |
Frequency | Hz | 50 | ||
Off circuit tapping links | % | ±2.5%, +-5% | Nil | Nil |
Connection | Delta | Star | Star | |
Vector group | Dy11y11 | |||
Insulation level (Maximum BIL/AC) | kV | 150/70 | 10/3 | 10/3 |
Winding material | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | |
Type of winding | Vacuum Resin Cast | Vacuum Resin cast | Vacuum Resin cast | |
Standard | AS 60076-11, AS 2374 | |||
Installation | Indoor | |||
Degree of protection | IP22 | |||
Type of cooling | AN/AF | |||
Installation altitude | < 1000 a.m.s.l | |||
Climatic/environmental And fire behaviour class | E2-C2-F1 |