Cart:

0 item(s) - $0.00
You have no items in your shopping cart.

Why dont you offer Multi step up Stepdown transformers?

We often get asked about the multiple use voltage converters which both stepdown to 110v and step-up up to 220v .

We not only don't sell them, we don't recommend them to our customers for some very important reasons:

Primarily they can damage your equipment due to under voltage.

Our engineer explains why this is so:

The technical Explanation of Step Down/Step Up Transformer Operation:

 

Note:

  1. On No load voltage = 120v
  2. On Full load voltage = 110v

 

So, if you try to reverse the transformer you feed 110v into a 120v winding to give not 240v you get 110 x 240/120 = 220v rms.

 

Hence, the voltage to the appliance is low. Now, if the applied voltage (input voltage) drops to 110-6% (as is allowed by the power utility supplier), the voltage will be 105.4 x

240/120 = 210.80v. This is VERY LOW!

 

Hence, the voltage will be so low on the 240v appliance. A motor with this voltage may stall due to the low voltage. The motor output power will be reduced to (210.8/240) x 100 = 77% output only.

  

Conclusion:

This is not satisfactory. You need a dedicated step up transformer for such an application and a dedicated step down transformer for that individual application.

You cannot successfully use a step down transformer in the reverse voltage operation method, to step up the voltage. It is incorrect and will cause under voltage problems on the customers equipment.