Single to Three Phase Converters
We have been busy in manufacturing working on multiple single to three phase converters for customers
We have been busy in manufacturing working on multiple single to three phase converters for customers
Tortech operations continue during the lockdown period in Sydney as an essential business to maintaining both medical and electrical service obligations.
Tortech operations continue during the lockdown period in Sydney as an essential business to maintaining both medical and electrical service obligations. Tortech is outside red zoned LGAs in Sydney and continues production as planned for current projects.
Tortech is open during the lockdown in Sydney as an essential business. For retail website customers - we only shipping to customers at the time.
Visit to UNSW by Tortech Engineers to discuss with UNSW team new Impulse testing techniques for voltage transformers. Thank-you to Professor Toan and lab technician Liu for this opportunity.
On our visit we tested a 11kV to 240v single Phase voltage transformer. Impulse tested at 120kV peak.
An impulse test is only of use if the detection method is sensitive enough to detect any breakdown inside the voltage transformer. With voltage transformers, there is a problem of detecting the breakdown due to lack of sensitivity.
RAAF air force base at Tindal near Darwin in NT. Transformers 350kva to 2500kva.
Due to the most recent developments in epoxy cast coil production, cooling has now been enhanced with new cooling duct material design . We even use metal cooling ducts to enhance the convection cooling with a conduction component.
Core structure rectangular, windings copper, cooling ducts in between windings outside the core window. This is a finite element computer calculation using ANSYS simulation computer software. Transformer ratings:Input 415V- output…
Ideal for testing laboratories, allows testing at different voltages and frequencies
Item 1 – Cast Resin type Isolation Transformer | HV Winding 1 | LV Winding 1 | LV Winding 2 | |
Rated power | kVA | 315 | 1250 | 1250 |
Rated voltage | kV | 33 | 0.48 | 0.48 |
Frequency | Hz | 50 | ||
Off circuit tapping links | % | ±2.5%, +-5% | Nil | Nil |
Connection | Delta | Star | Star | |
Vector group | Dy11y11 | |||
Insulation level (Maximum BIL/AC) | kV | 150/70 | 10/3 | 10/3 |
Winding material | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | |
Type of winding | Vacuum Resin Cast | Vacuum Resin cast | Vacuum Resin cast | |
Standard | AS 60076-11, AS 2374 | |||
Installation | Indoor | |||
Degree of protection | IP22 | |||
Type of cooling | AN/AF | |||
Installation altitude | < 1000 a.m.s.l | |||
Climatic/environmental And fire behaviour class | E2-C2-F1 |
0 items in the cart ($0.00)