20kw DC Output 100v – 200-300v DC Power Supply
One more project we proud of in 2020! A 20kw DC output 100v - 200-300v DC Power supply with 415v 3phase in. IP56 outdoor rated for a robust environment.
One more project we proud of in 2020! A 20kw DC output 100v - 200-300v DC Power supply with 415v 3phase in. IP56 outdoor rated for a robust environment.
Tortech will close for Christmas at 12 pm on Tuesday the 22nd December 2020 and will resume full production on Monday the 11th January 2021. Last day for processing orders…
3 phase outdoor transformer250kVA 400V, stainless steel enclosure, IP56 for outdoor operation.Railyway application, Class H insulation. Temp rise tested to 100deg CUnique robust design
Great news Tortech is now accepting Zip Pay as you go Interest free payments for a variety of products online! Rather than paying the full amount via Visa or Mastercard,…
New 600va Single to Three Phase Testing Unit. It models the 3 phase 415v grid, as an output voltage of 41.5v phase to phase IT IS SAFE FOR STUDENTS In TAFE…
400v in 400v outDYn11 Indoor rated 155deg Insulation class 15kva rated 3 Phase+- tapped primarys
10kVA 415 to 380v 3-Phase American European Auto-Transformers. An ideal solution if you want to run an Overseas device rated at 380VAC in Australia. In stock, ready to go!
Medical Isolation transformers by Tortech tested to EN60601-1. These transformers Protect sensitive equipment from EMI/FI line noise and power surges. Ideal for protecting sensitive electronic equipment in patient care facilities.Supplied…
We are proud to be featured in the Engineers’ Tribune - a group of engineers and technical writers who wanted to explore the ins and outs of technology as it…
Joint Institution Lecture Series Date: Thursday 5th November 2020Time: 18:00 (6pm) AEST The effect of voltage harmonics on three phase transformer core losses. Topics to be discussed include: Harmonics and…
Item 1 – Cast Resin type Isolation Transformer | HV Winding 1 | LV Winding 1 | LV Winding 2 | |
Rated power | kVA | 315 | 1250 | 1250 |
Rated voltage | kV | 33 | 0.48 | 0.48 |
Frequency | Hz | 50 | ||
Off circuit tapping links | % | ±2.5%, +-5% | Nil | Nil |
Connection | Delta | Star | Star | |
Vector group | Dy11y11 | |||
Insulation level (Maximum BIL/AC) | kV | 150/70 | 10/3 | 10/3 |
Winding material | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | Aluminium cast windings in quartz filled self-extinguishing epoxy resin | |
Type of winding | Vacuum Resin Cast | Vacuum Resin cast | Vacuum Resin cast | |
Standard | AS 60076-11, AS 2374 | |||
Installation | Indoor | |||
Degree of protection | IP22 | |||
Type of cooling | AN/AF | |||
Installation altitude | < 1000 a.m.s.l | |||
Climatic/environmental And fire behaviour class | E2-C2-F1 |