Toroidal Transformers

Toroidal Transformers for universal Applications

Open Wound 230V Transformers:

High quality open style toroidal transformers with a single 230V a.c. 50/60Hz primary winding. Twin secondary windings may be connected in series or parallel or used independently.
· Small size and low weight compared with traditional stacked lamination types
· Extremely low level of radiated magnetic field
· Very low induced noise (hum)
· Very low iron loss
· Double insulated primary leads
· Supplied with mounting kit
· 100% electrical and flash tested
· High quality manufacturing and testing in accordance to EN61558, EN60742, EN60950, EN60065, VDE0551, VDE0550 and BS415

Important Installation Note
Each transformer is supplied with a dished washer and protection pads for single hole fixing. Ensure that the pads are fitted above and below the transformer winding and that the dished washer is on top of the upper pad. Do not overtighten the fixing bolt (not supplied) as this could damage the winding.
Under no circumstances should both ends of the fixing bolt contact a metal chassis or frame as this would create a 'shorted turn' causing irreparable damage.

Rated

VA

Part Number

(xxx=Sec voltage)

Regulation

% Typical

Temperature

Rise [K]

Dimensions*

Diameter [mm]

Height

[mm]

Weight

[Kg]

15

0015P1-2-xxx

16

26

60

31

0.30

30

0030P1-2-xxx

18

40

70

32

0.45

50

0050P1-2-xxx

14

42

80

33

0.65

80

0080P1-2-xxx

14

53

93

38

0.90

120

0120P1-2-xxx

10

52

93

46

1.20

160

0160P1-2-xxx

9

55

105

42

1.50

225

0225P1-2-xxx

8

60

112

47

1.90

300

0300P1-2-xxx

8

60

115

58

2.30

500

0500P1-2-xxx

6

68

136

60

3.50

625

0625P1-2-xxx

5

67

136

68

4.30

800

0800P1-2-xxx

5

69

162

60

5.10

1000

1000P1-2-xxx

5

72

162

70

6.50

* Allow extra 4mm for mounting kit, allow extra 5mm where leads emerge

Leads: PVC insulated 150mm long.

Secondary voltage tolerance: <1% at nominal input

Overall insulation category: Class A 105°C

Maximum ambient operating temperature +40°C

Neoprene pads: 5kV isolation

Meets all requirements of Class E (120°C)

  • Please Note: Details are subject to change without written notification.

  • Tortech’s Design format, facilitates a wide range of Input & Output Voltages, configurations and termination possibilities. Please discuss your specific requirements with our sales staff.

 

  BACK HOME   Transformers    Company Profile     Contact   Links    EMAIL us    We Accept:credit.gif (20467 bytes)

Transformer Request for Quote Updated 10 September 2003 01:00 AM