Toroidal Transformers
Toroidal Transformers for universal Applications
Open Wound 230V Transformers:
High quality open style toroidal
transformers with a single 230V a.c. 50/60Hz primary winding. Twin secondary
windings may be connected in series or parallel or used independently.
· Small size and low weight compared with traditional stacked lamination types
· Extremely low level of radiated magnetic field
· Very low induced noise (hum)
· Very low iron loss
· Double insulated primary leads
· Supplied with mounting kit
· 100% electrical and flash tested
· High quality manufacturing and testing in accordance to EN61558, EN60742,
EN60950, EN60065, VDE0551, VDE0550 and BS415
Important Installation
Note
Each transformer is supplied with a dished washer and protection pads for single
hole fixing. Ensure that the pads are fitted above and below the transformer
winding and that the dished washer is on top of the upper pad. Do not
overtighten the fixing bolt (not supplied) as this could damage the winding.
Under no circumstances should both ends of the fixing bolt contact a metal
chassis or frame as this would create a 'shorted turn' causing irreparable
damage.
|
Rated VA |
Part Number (xxx=Sec voltage) |
Regulation % Typical |
Temperature Rise [K] |
Dimensions* Diameter [mm] |
Height [mm] |
Weight [Kg] |
|
15 |
0015P1-2-xxx |
16 |
26 |
60 |
31 |
0.30 |
|
30 |
0030P1-2-xxx |
18 |
40 |
70 |
32 |
0.45 |
|
50 |
0050P1-2-xxx |
14 |
42 |
80 |
33 |
0.65 |
|
80 |
0080P1-2-xxx |
14 |
53 |
93 |
38 |
0.90 |
|
120 |
0120P1-2-xxx |
10 |
52 |
93 |
46 |
1.20 |
|
160 |
0160P1-2-xxx |
9 |
55 |
105 |
42 |
1.50 |
|
225 |
0225P1-2-xxx |
8 |
60 |
112 |
47 |
1.90 |
|
300 |
0300P1-2-xxx |
8 |
60 |
115 |
58 |
2.30 |
|
500 |
0500P1-2-xxx |
6 |
68 |
136 |
60 |
3.50 |
|
625 |
0625P1-2-xxx |
5 |
67 |
136 |
68 |
4.30 |
|
800 |
0800P1-2-xxx |
5 |
69 |
162 |
60 |
5.10 |
|
1000 |
1000P1-2-xxx |
5 |
72 |
162 |
70 |
6.50 |
|
* Allow extra 4mm for mounting kit, allow extra 5mm where leads emerge |
|
Leads: PVC insulated 150mm long. |
|
Secondary voltage tolerance: <1% at nominal input |
|
Overall insulation category: Class A 105°C |
|
Maximum ambient operating temperature +40°C |
|
Neoprene pads: 5kV isolation |
|
Meets all requirements of Class E (120°C)
|
|
BACK HOME Transformers Company Profile
Contact Links
EMAIL us We
Accept: |
Updated 10 September 2003 01:00 AM