Important differences Between Isolated and Auto Transformer Design When it comes to safety it is very important to note there are 2 major differences in step down transformer design: There are 2 types of stepdown transformers, the economy units are what we call "auto" transformers . Tortech sells both Isolated and auto stepdown transformers. We normally recommend Isolated transformers for equipment that is of significant value, runs continuously and needs reliable and consistent use. Isolated means in the transformer the voltage is isolated from input to output. This protects your USA device from the higher 240V Aussie power voltage - making it is impossible for the 240v power to "cross over" into your USA appliance which may happen during a power surge. Comparison Table:
Isolated Transformer: Transformer with two separate input and output windings - note below - the isolation between input and output. This ensures protection for your USA or Japanese appliance so that in case of power surge your appliance is fully isolated from the input power supply:
Auto Transformer: As you can see below your appliance has direct connection to input and this leaves it vulnerable to surges and over current:
The safety differences: Safety is a major consideration for any power transformer (and in the case of telecommunications, the isolating transformers), and electrical contact between primary and secondary must not be allowed under any realistic fault condition. All countries have safety standards that apply to transformers where electrical isolation is important, and if in any doubt about the safety of a transformer for a particular purpose, make sure that you verify that the transformer complies with the relevant standard(s). It is well beyond the scope of this article to cover all the possibilities of standards and compliance issues. Many power transformers are fitted with an internal thermal fuse that will become open circuit in the event that a preset temperature is exceeded. This temperature is chosen to be the maximum safe temperature of the windings before the insulation melts or breaks down, so in the event of a fault, the thermal fuse will open before the insulation is damaged and the component becomes potentially dangerous. It also helps to prevent the risk of fire . See Figure (below) as an example of how bad things can get if the transformer is not protected. Once the thermal fuse opens, the transformer must be discarded, as it is usually not possible to gain access to the fuse for replacement. This is not as silly as it may sound, since the thermal effects on the insulation cannot be predicted, and the transformer may be unsafe if it were still able to be used. Diagram of Auto-Transformer failure:
Proper safety earthing is the only real way to ensure that a transformer that fails catastrophically (such as that shown) does not cause the chassis to become live - not all transformers are created equal when safety is concerned. Correct fusing will ensure that the fuse blows - hopefully before the electrical safety is compromised. A thermal fuse would have prevented the situation from becoming as bad as shown, but the transformer would have been just as dead. Why do Isolated Stepdowns Transformers have no Earth? (diagram) < No products > |