DP split core CT transformersSplit core current CT transformers have interleaved joint and hinge structure.

Split core CTs have a removable section, so that they can be installed without interrupting the circuit.

A split core current transformer for coupling monitoring apparatus to a current carrying conductor includes a two-piece annular core structure formed by first and second arcuate core assemblies having windings, connectable to the monitoring apparatus, wound on laminated core sections, the laminated core sections each including a plurality of flat lamination elements arranged in a stacked configuration with alternate elements having generally circular end portions which project beyond the main body portion of the arcuate core section at each end thereof defining generally circular gaps....
 

Technical Details of split core transformers

Primary current: 100A-5000A 
Secondary current: 5A, 1A 
Standard approval: IEC44-1, BS7626 
Maximum voltage: 0.72/3kV 
Frequency: 50/60Hz 
Rated load: 1VA-30VA 
Class: 0.5, 1.0, 3.0 
Short-time thermal current: Ith=100¡ÁIn 
Rated security coefficient: FS 

 
Type
A
B
C
D
E
F
G
H
I
Weight(kg)
DP-23
20
30
51
89
111
34
47
40
32
0.75
DP-58
50
80
78
114
145
32
32
32
33
0.90
DP-88
80
80
108
144
145
32
32
32
33
1.05
DP-812
80
120
108
144
185
32
32
32
33
1.25
DP-816
80
160
120
184
245
52
47
52
38
4.30


 
split-core size (AxB)
DP-23 20x30mm
DP-58 50x80mm
DP-88 80x80mm
DP-812 80x120mm
DP-816 80x160mm
split core transformersplit-core  ct current transformer

 

Split core current transformers DP series:
The DP series of current transformers have been especially designed to facilitate their installation in new or already existing networks. 
Thanks to its split core they may be installed without opening any cable or bus bar circuit. 
The connection of conventional CTs usually requires the interruption of the primary side circuit to pass cables or bus bars through the transformer core or to connect such cables to the primary terminals. The DP series transformers core may be easily opened and they may be installed and connected without any supply interruption, thus saving time and installation costs.
The main features of DP transformers are:
-Small size and easy mounting 
-Wide inner window, allowing clamping of big cables or bus bars
-Wide range of sizes to accomodate all the existing installations 
-High accuracy and reliability
Split core current transformers DP series:
Primary current: 
Secondary current: 
Standard approval: 
Maximum voltage: 
Frequency: 
Rated load: 
Class: 
Short-time thermal current: 
100A-5000A
5A, 1A
IEC44-1, BS7626
0.72/3kV
50/60Hz
1VA-30VA
0.5, 1.0, 3.0
 
Technical data & Specification:
Model
A
B
C
D
E
F
G
H
I
Weight(kg)
DP-23
20
30
51
89
111
34
47
40
32
0.75
DP-58
50
80
78
114
145
32
32
32
33
0.90
DP-88
80
80
108
144
145
32
32
32
33
1.05
DP-812
80
120
108
144
185
32
32
32
33
1.25
DP-816
80
160
120
184
245
52
52
52
38
4.3
Model
Nominal
current ratio
 
Class:0.5
VA
DP-23
100
-
150
-
200
-
250
-
300
1.5
400
2.5
DP-58
250
1.5
300
1.5
400
1.5
500
2.5
600
2.5
750
2.5
800
2.5
1000
5
DP-88
250
1.5
300
1.5
400
1.5
500
2.5
600
2.5
750
2.5
800
2.5
1000
5
DP-812
500
2.5
600
2.5
750
2.5
800
2.5
1000
6
1200
6
1250
7.5
1500
7.5
DP-816
1000
1.
1500
15
2000
15
2500
15
3000
20
4000
20
5000
20
Outline drawing:
 Currently Available in 5 Amp  Secondary Only
Model Nominal current ratio Burden VA
Class: 0,5 Class:1
VA VA 
DP-23 100/5
150/5
200/5 1.5
250/5 2
300/5 1.5 3.75
400/5 2.5 6
DP-58 250/5 1.5 2
300/5 1.5 3
400/5 1.5 3
500/5 2.5 5
600/5 2.5 5
750/5 2.5 6
800/5 2.5 7.5
1000/5 5 10
DP-88 250/5 1.5 3.75
300/5 1.5 6
400/5 1.5 10
500/5 2.5 15
600/5 2.5 17.5
750/5 2.5 18
800/5 2.5 18
1000/5 5 20
DP-812 500/5 2.5 12
600/5 2.5 15
750/5 2.5 17.5
800/5 2.5 18
1000/5 5 20
1200/5 6 25
1250/5 7.5 25
1500/5 7.5 30
DP-816 1000/5 10 20
1500/5 15 25
2000/5 15 25
2500/5 15 25
3000/5 20 30
4000/5 20 30
5000/5 20 30




 





 

Click Here to download this data-sheet as a PDF fileAC Series - Quick Reference Guide (29 kB)  

Applications
 
  • Sensing Overload Current
  • Ground fault detection
  • Metering
  • Analog to Digital circuits

Features
 

  • Excellent quality at extremely competitive pricing due to high volume production
  • Manufactured in ISO-9001 approved Talema facility

Click on the PDF icons below to open the PDF datasheets
 

Part No. Primary Current Turns Ratio Net Weight
  AC1005 5 Amps 1000:1 16.3 grams
  AC1010 10 Amps 1000:1 16.3 grams
  AC1015 15 Amps 1000:1 16.3 grams
  AC1020 20 Amps 1000:1 16.3 grams
  AC1025 25 Amps 1000:1 35.5 grams
  AC1030 30 Amps 1000:1 35.5 grams
  AC1040 40 Amps 1000:1 47.3 grams
  AC1050 50 Amps 1000:1 47.3 grams
  AC1060 60 Amps 1000:1 65.2 grams
  AC1075 75 Amps 1000:1 65.2 grams
  AC1100 100 Amps 1000:1 80.0 grams
  AC1150 150 Amps 1000:1 150.0 grams
  AC1200 200 Amps 1000:1 150.0 grams