Resin Cast Transformers

Resin Cast Transformers Up to 3.5 MVA & 33kV

Resin Cast Isolation transformers can be used in installations which require a Fire rating class of F1.
The transformers are designed to operate under natural convection of air. They can also be manufactured with a cross flow fan for controlled by the temperature controller for forced cooling to
allow operation under extreme Australian conditions.


Resin cast transformer range is commonly used for Photovoltaic grid systems, Railway and UPS isolation systems. The transformers are routine tested for partial discharge <10pC and can also be impulse tested up to 400kV

1 This transformer is rated F1 fire behaviour class, it is fire retardant and pollution free and can be directly installed close
to load.
2 Maintenance free transformer and allows simple installation and low operating cost
3 This transformer shows excellent resistance to moisture and operates normally in regions with relative humidity of 100%.
4 This transformer design features compact size and weight, low loss and noise level, high mechanical strength, low partial
discharge (under 10pC).
5 The optional temperature probe and control system offers reliable protection to ensure safe operation.
6 The transformer conforms to AS 60076 and IEC 726


Submit Enquiry here for a custom quotation:

RATED POWER (KVA) INPUT/OUTPUT VOLTAGE (V) FREQUENCY (Hz) INSULTAION CLASS EFFICIENCY SIZE (mm) WEIGHT (Kg)
AMORPHOUS CORE CRGO CORE
100 270/350/415 50/60 F/H/C 98.9 98.4 730 x 500 x 816 600
160 270/350/415 50/60 F/H/C 99.0 98.4 950 x 650 x1124 850
200 270/350/415 50/60 F/H/C 99.1 98.6 990 x 650 x 1164 950
315 270/350/415 50/60 F/H/C 99.2 98.8 1050 x 750 x 1320  1250
500 270/350/415 50/60 F/H/C 99.3 98.8 1140 x 800 x 1430  1850
800 270/350/415 50/60 F/H/C 99.3 98.8 1330 x 800 x 1540 2200
1000 270/350/415 50/60 F/H/C 99.3 98.8 1400 x 960 x 1640 2750
1600 270/350/415 50/60 F/H/C 99.3 98.8 1560 x 960 x 1840 4000
2000 270/350/415 50/60 F/H/C 99.3 98.8 1680 x 960 x 1930 4800
2500 270/350/415 50/60 F/H/C 99.4 98.8 1720 x 1010 x 1950 5500

10 Item(s)

List  Grid 

Set Descending Direction
  1. 100 kVA THREE PHASE ISOLATION TRANSFORMERS
  2. 160 kVA THREE PHASE ISOLATION TRANSFORMERS
  3. 200 kVA THREE PHASE ISOLATION TRANSFORMERS
  4. 315 kVA THREE PHASE ISOLATION TRANSFORMERS
  5. 500 kVA THREE PHASE ISOLATION TRANSFORMERS
  6. 800 kVA THREE PHASE ISOLATION TRANSFORMERS
  7. 1000 kVA THREE PHASE ISOLATION TRANSFORMERS
  8. 1600 kVA THREE PHASE ISOLATION TRANSFORMERS
  9. 2000 kVA THREE PHASE ISOLATION TRANSFORMERS
  10. 2500 kVA THREE PHASE ISOLATION TRANSFORMERS

10 Item(s)

List  Grid 

Set Descending Direction