Why do I need it?
All our local main power distribution is
unbalanced. So its vulnerable to interference in the same
way as unbalanced audio lines, and there is plenty of
interference to pick up: from motors, fluorescent lights,
switch-mode power supplies and dozens of other reactive
loads. All of these feed spurious harmonics and out of phase
components back into the mains. The more devices on the
circuit, the more these reactive currents can go into the
earthing system. The resulting noise in your grounding
system is a major contributor to a studios “noise floor”-
that stubborn residual noise and hum you just cant get rid
of, Star earthing scheme, power conditioning and cable
routing cant solve it. The Balance Studio Power Supply
eliminates these reactive power components in exactly the
same way as balanced audio circuits eliminate external
noise. The reactive currents in a balanced power circuit sum
to zero at the power supplys earth.
You will immediately notice everything is
quieter. There is an audible improvement in frequency
response and stereo imaging. Even digital transfers are
cleaner.
How does it remove power line noise?
Transformers only respond to voltage differences between
their leads. Power lines often have a type of noise called common
mode noise which
is present on both the neutral and hot wire. The Balanced
Power Supply contains a massive toroid transformer that
reject much of this noise.
But what about noise on just the hot wire?
The output of the Balanced Power Supply contains heavy
filtering to eliminate much of this noise. Often times,
audio equipment itself generates noise that gets fed back
into the power line. The noise is then free to invade other
equipment. Power amps with laminated power transformers can
be the worst offenders. The heavy filtering on the output
can help to eliminate much of this noise.
What is a ground loop?
A ground loop occurs when different equipment grounds
are at different voltages, causing noisy ground currents to
flow between them. The Balanced Power Supply creates a new
ground called a derived
ground, that decouples equipment connected to it from
these circulating ground currents in the rest of the house
wiring. It also provides one common ground reference for
all the equipment connected to it.
How does it reduce radiated fields?
Because the power is delivered by two out of phase
signals, the electric fields produced by each should largely
cancel. This reduces noise caused by radiated fields. This
is same principal used with twisted pair cable but in
reverse. Instead of rejecting noise, power carrying cables
dont radiate noise in the first place.
How does if reduce interference between equipment?
Most modern
electronic equipment uses switching regulators in their
power supplies. These devices can produce RF noise that can
couple through the power cord to other equipment. The
balanced power supply provides a very low impedance to the
connected equipment which shorts out this high frequency
noise. Some users have reported improvements in large
screen video performance.
How does the unit provide a soft start?
By using a simple and reliable thermal device, inrush
currents on start up are greatly reduced. As the thermal
device heats up in a few seconds, normal power currents are
restored. Very simple. Very effective.
|